Fire Safety Awareness & Enforcement

Shared by a Flashcards.gg user · generated with AI · Report this set

This set covers essential fire safety principles, hazard prevention rules, and emergency enforcement procedures.

52 cards English Level: Intermediate First aid Published
Tap the card to flip it

Cards · 52

Fire Triangle
The model representing the three essential elements needed to ignite and sustain fire: fuel, oxygen, and heat.
Fire Tetrahedron
An updated combustion model adding a fourth element, the uninhibited chemical chain reaction, to heat, fuel, and oxygen.
Class A Fire
Fires involving ordinary combustible materials such as wood, paper, cloth, trash, and plastics.
Class B Fire
Fires involving flammable or combustible liquids and gases such as gasoline, oil, paint, propane, and solvents.
Class C Fire
Fires involving energized electrical equipment such as appliances, wiring, circuit breakers, and machinery.
Class D Fire
Fires involving combustible metals such as magnesium, titanium, zirconium, sodium, and potassium.
Class K Fire
Fires involving commercial cooking media such as vegetable oils, animal fats, and grease.
PASS Technique
The standard four-step method for using a fire extinguisher: Pull the pin, Aim at the base, Squeeze the lever, and Sweep.
RACE Protocol
Emergency response sequence: Rescue anyone in immediate danger, Alarm the facility, Contain the fire, and Extinguish or Evacuate.
Flashover
The near-simultaneous ignition of all exposed combustible material in an enclosed space due to thermal radiation.
Backdraft
An explosive event occurring when fresh oxygen is suddenly introduced into an oxygen-starved, heat-saturated compartment.
Means of Egress
A continuous and unobstructed path of vertical and horizontal travel from any point in a building to a public way.
Exit Access
The portion of a means of egress system that leads from any occupied point in a building to an exit.
Exit Discharge
The section of a means of egress between the termination of an exit and a public way.
Fire Door Assembly
A rated protective barrier comprising door, frame, and hardware designed to resist the spread of fire and smoke.
Fire Resistance Rating
The duration in minutes or hours that a building component withstands exposure to a standardized test fire.
Fire Damper
A device installed in air distribution ducts that automatically closes to restrict the passage of flame during a fire.
Smoke Damper
A mechanical device operated by a smoke sensor designed to resist the flow of smoke within HVAC ductwork.
Intumescent Coating
A fire-retardant substance that swells upon heat exposure to create an insulating char layer over structural members.
Fire Load
The total amount of heat energy that would be released by the combustion of all fuel present in a defined space.
Smoke Alarm
A self-contained device that senses smoke and sounds an audible or visual alarm in the immediate area.
Photoelectric Smoke Detector
A detector using light beam obstruction or scattering, highly responsive to slow, smoldering fires.
Ionization Smoke Detector
A detector containing radioactive material that senses electrical current changes, optimal for fast-flaming fires.
Heat Detector
A sensor triggered by high temperature or rapid temperature increase, commonly used where smoke causes false alarms.
Manual Pull Station
A wall-mounted initiation device requiring human action to sound the building's fire alarm system.
Automatic Sprinkler System
A network of overhead pipes and heat-activated sprinkler heads that automatically discharges water over a fire.
Wet Pipe System
A sprinkler system filled with pressurized water that discharges immediately when a sprinkler head opens.
Dry Pipe System
A sprinkler network filled with pressurized air or nitrogen used in freezing environments where water enters upon activation.
Pre-Action Sprinkler System
A dry system requiring both a detection event and heat activation before water floods the pipes and sprays.
Standpipe System
Piping within a building with hose connection points that provides water supply for manual firefighting operations.
Fire Department Connection (FDC)
An external building fitting allowing firefighters to pump supplemental water into sprinkler or standpipe systems.
Occupant Load
The total number of persons for which the means of egress of a building or space is legally calculated and approved.
Emergency Evacuation Plan
A documented strategy outlining escape routes, assembly points, responsibilities, and procedures during an emergency.
Assembly Point
A designated safe outdoor area where building occupants must gather and account for all individuals after evacuation.
Fire Warden
An assigned individual responsible for guiding evacuations, inspecting hazards, and accounting for personnel.
Hot Work Permit
A formal written authorization required before performing operations involving open flames or sparks, like welding.
Fire Watch
Dedicated personnel assigned to continuously monitor an area for fires during hot work or when protection systems are offline.
Flammable Liquid Storage Cabinet
A specialized double-walled steel enclosure designed to protect flammable chemicals from external fire exposure.
Housekeeping in Fire Prevention
The systematic removal of combustible waste, clear aisle maintenance, and safe chemical storage to reduce fire risk.
Daisy Chaining
The unsafe practice of connecting multiple power strips or extension cords together, creating an electrical fire hazard.
Authority Having Jurisdiction (AHJ)
The organization, office, or individual responsible for enforcing fire codes and approving fire equipment and procedures.
Fire Safety Audit
A comprehensive systematic evaluation of an organization's fire safety measures, policies, and code compliance.
Notice of Violation
An official written notification from a fire inspector identifying code infractions that must be corrected within a deadline.
Stop Work Order
A legally binding directive issued by an enforcement officer halting construction or operations due to critical fire risks.
Certificate of Occupancy
A document issued by local authorities certifying that a building complies with applicable fire and safety codes for use.
Fire Risk Assessment (FRA)
A structured review identifying potential fire hazards, people at risk, and the measures necessary to minimize threats.
Clearance Around Sprinklers
The mandatory minimum vertical distance, usually 18 to 36 inches, maintained below sprinkler heads to ensure water coverage.
Emergency Lighting
Battery-backed lighting devices that illuminate egress paths automatically during power outages.
Panic Hardware
A mechanical crash bar on exit doors that allows rapid unlatching and egress without prior knowledge or keys.
Hydrant Clearance Requirement
The designated open space, typically three feet around a fire hydrant, required for immediate emergency hose connection.
Combustible Dust Hazard
Fine solid particles that suspended in air can ignite rapidly and generate severe secondary explosions.
Defensible Space
A buffer zone created by clearing vegetation around a structure to slow wildfire advance and aid firefighting efforts.